Advanced Commands

D3842 Rev B

EZ3600 User’s Manual

17

Re-Use Recipe/Pen Data

1. Indicator .
2. Press and hold .
3. Press , while holding

indicator scrolls:

On=Clear Clear=Reuse
Net=exit

.

Release .

4. Press again to re-use

recipe and pen data.

Note

: When re-using data stored in indicator, it takes recipe and pen

information and removes completed weights loaded or unloaded and

marks them undone. It will not accumulate data day to day. Download data

to USB Drive before re-using recipe and pen data stored.

Note:

For continuous re-use, set D.A.N.

466

to on. See page 37.

Mix Timer

The mix timer allows the operator to

set a timer to alert the operator

when the mixing is completed. This

can be manually entered or entered

as part of the recipe using the TMR

TRACKER or other software

package.

1. Press .

2. Use the numeric keypad to

enter the amount of time.

3. Press .

4. The Mix Timer will begin to

count down. When it reaches

zero, the alarm light and buzzer

will turn on.

5. Press to enter the

weighing mode.

6. Press the or key to re-

enter the batching mode.