9850 hold hold – Digi-Star EZ 2000/V User Manual

Page 6

Advertising
background image

Digi-Star Model EZ2000/EZ2000V

2. System operation

4

TO EXIT HOLD MODE

Press

.

At this time the scale adjusts the Zero/Balance to
maintain the gross weight displayed. Small
changes in weight can occur while moving the
scale system to new locations for loading or
unloading. This change us called "zero shift" and
is due to several factors including terrain changes
and mechanical stresses.

TO CANCEL HOLD MODE

Press

.

Cancelling the Hold mode prevents the scale from
adjusting the Zero/Balance and returns the system
to the normal weighing mode. Use this if you
choose Hold Mode in error.

USING FUNCTION & SELECT KEYS

The FUNCTION key provides additional features
to the operation of the scale. The FUNCTION key
is similar to the F1 key of a computer. The
SELECT key is used to determine what operation
will occur when the FUNCTION key is pressed.

Press

to display the current operation of the

FUNCTION key.

Continue to press

until the desired operation

is displayed.

!

The FUNCTION key maintains this operation

until

is pressed again.

Now press the

key to perform the displayed

operation.

For example, if the word TIMER is displayed, then pressing the FUNCTION key will activate the
Mix Timer. If the message M+ is displayed, then pressing the FUNCTION key will cause the scale
to perform the Memory Plus (M+) operation.

The FUNCTION key operation is stored in non-volatile memory. This allows the scale to
remember the operation of the FUNCTION key even when the unit is turned OFF.

Press the SELECT key once to display the operation currently assigned to the FUNCTION key.

9850

HOLD

HOLD

1

2

Advertising