Menus and Calibration

D3714 Rev C

EZ3400 User’s Manual

35

SETTING

[display]

D.A.N

NO.

OPTIONS [displayed]

BOLD=DEFAULT

DESCRIPTION

DRIVE RATIO

(dratio)

422

0001.00

Enter the number of

input pulses that equal

1 mixer revolution.

GROSS SET

POINT

(SETPNT)

423

5000

Set a gross weight in

long form that will

activate +12VDC Alarm

Output on Power cord.

GROSS SET

POINT CHNG

(SETCHG)

424

500

Set required weight

change to turn off

+12VDC Alarm Output.

GROSS SET

POINT DELAY

(SETDEL)

425

0

-10

Set the time delay that

must expire before the

+12VDC Alarm Output

can Turn On/Off.

GROSS SET PNT

OUTPUT

(SETOUT)

426

OVER/

UNDER

Select when the

+12VDC Alarm Output

becomes active.

SET POINT

COUNT

(SET CTR)

427

0

-9

Counts activation of

Code 423

ENTRY METHOD
(E MTHD)

441

1

,2,3

Select batch 1-

amount/animal

2-percent/load

3- amount/load

TOLERANCE

(toler)

442

OFF

,.5,1-5,7,10

Select tolerance weight

percentage to accept

ingredient.

INGR. ADVANCE

DELAY

(delay)

443

MANUAL

, 1-

3,5,7,10,20,30,60

Select seconds to delay

before advancing to

next ingredient.

INGREDIENT

NAMES

(INGRNM)

444

ON/

OFF

If ON displays

ingredient names while

batching

ACCUMULATION

(ACCUM)

445

ON/

OFF

If ON ingredient weights

are accumulated while

batching

INGREDIENT RE-

SIZING
(INGSIZ)

449

1-ING

/OFF

Selects automatic

ingredient re-size mode

PISPLAY SCOOP

%

(SCOOP%)

452

ON

/OFF

If ON displays scoop %

to load