Power connection, Load cell connection – Digi-Star Landoll 5210 User Manual

Page 10

Advertising
background image

Indicator Mounting

8

Landoll 5210 Grain Drill Scale Kit

D3949-US-Rev A

INDICATOR MOUNTING

The scale indicator can be mounted in the tractor cab or on the drill with swivel mounting pack (406081). Two

cables must be connected to the indicator bottom panel, J-Box and power cables. Refer to Indicator Manual

D3831-US for details of indicator mounting options and connection of power cord.

U-BOLT MOUNTING

TRACTOR CAB MOUNTING

1. Bolt the readout in the cab with the bracket, or mount the bracket in the front of the lift cylinder.

2. Install power cord to a 12-volt negative ground battery.

3. Route J-box cable to indicator and install to indicator bottom panel.

4. Program indicator with the following set-up and calibration number (see Indicator manual).

4-pt (4 Load Cells) Dual Hopper set-up #114008 calibration #1532

2-pt (2 Load Cells) Single Hopper set-up #114004 calibration #778

Power Connection:

The power cable should be connected directly to a vehicle battery or regulated power supply. The scale end of

the power cable is attached to the J901 connector located on the bottom panel of the indicator.

Connect the RED wire from the power cable to +12 VDC and the BLACK wire to GROUND. The indicator is

fused internally at 4 amps.

Power Cable Connections:

Wire color Wire Function

Red

Battery (+12 VDC)

Black

GROUND

Load Cell Connection:

The indicator is designed to operate with strain gage load cells. The indicator will normally be supplied with a

“J-BOX” cable going between the scale and the load cell junction box.

Load Cell Wire Digi-Star Function

1

RED

+EX

2

GREEN

-SIG

3

WHITE

+SIG

4

BLACK

-EX

5

CLEAR

SHIELD

INDICATOR MOUNTINGS

Advertising