Digi-Star RD 400 User Manual

Page 3

Advertising
background image

Installation Manual

D3671

If installation requires the cable to be removed from the Remote:

1. Remove the nine (9) screws to remove the rear panel of the

RD 400.

2. Loosen the five (5) screws on the terminal block at the

bottom edge of the circuit board. Pull each wire out of the

terminal block.

3. Loosen the plastic nut on the cable strain relief on the

bottom panel of the enclosure and pull the cable out of the

enclosure.

4. After routing the cable back to the RD 400, insert the cable

through the cable strain relief. Tighten strain relief nut

snugly using a wrench. Do not over-tighten.

RED

WHITE

BLACK

YELLOW

5. Place the wires in their correct locations as marked on the

circuit board and tighten the screws on the terminal blocks

securely.

Note: Blue and Orange wires are not used.

6. Connect the RD 400 cable to the “REMOTE” connector on

your EZ indicator and verify that the unit works properly. If

RD 400 does not work properly, check the terminal block

connections.

7. Install the rear cover using the nine (9) screws.