Digi-Star RD 400 User Manual

Page 4

Advertising
background image

RD 400

On EZ150, EZ210, EZ320 Indicators Only

The Original EZ series indicator (EZ150,EZ210, EZ320) can be

setup to work with either an old Model 20R or the newer RD

series remote display. When set incorrectly for a 20R, the RD

400 displays nonsense even when connected to an EZ indicator

that is working properly. Follow these six steps to change the

setup in the EZ indicator for the correct style of Remote Display:

8. Press and hold [NET/GROSS], then press and hold [ON].
9. Press [ON] several times until the message “PRESS

NET/GROSS FOR CALIBRATION - TARE FOR SETUP -

ON TO EXIT” scrolls across the display.

10. Press [TARE] to enter Section 3 of the “Long Form Setup”.
11. Press [ON] several times until the message “REMOTE” is

displayed.

12. Press [NET/GROSS] to select “EZ R” for both EZ Series and

RD Series Remote Displays.

13. Press [ON].
14. Press and hold [TARE], then press [ON] to exit setup.
15. The Remote now displays the same information as the EZ

indicator.