4.7.2

Maximum forces and moments allowed on MJ Slurry pump flanges

Maximum forces (F) in N (lbf) and moments (M) in

Nm (lbf•ft)

Discharge

Flange Size

DN

(in.)

Mx My Mz Fx Fy Fz

50

(2)

460

(340)

230

(170)

350

(260)

710

(160)

580

(130)

890

(200)

65

(2-1/2)

710

(520)

350

(260)

540

(400)

890

(200)

760

(170)

1110

(250)

80

(3)

950

(700)

470

(350)

720

(530)

1070

(240)

890

(200)

1330

(300)

100

(4)

1330

(980)

680

(500)

1000

(740)

1420

(320)

1160

(260)

1780

(400)

125

(5)

1830

(1340)

940

(690)

1450

(1070)

1960

(440)

1600

(360)

2450

(550)

150

(6)

2300

(1700)

1180

(870)

1780

(1300)

2490

(560)

2050

(460)

3110

(700)

200

(8)

3530

(2600)

1760

(1300)

2580

(1900)

3780

(850)

3110

(700)

4890

(1100)

250

(10)

5020

(3700)

2440

(1800)

3800

(2800)

5340

(1200)

4450

(1000)

6670

(1500)

300

(12)

6100

(4500)

2980

(2200)

4610

(3400)

6670

(1500)

5340

(1200)

8000

(1800)

Notes:
1) F = External force (tension or compression)

M = External moment, clockwise or counter-clockwise

2) Forces and moments may be applied simultaneously in any

direction.

3) Values apply to all materials.
4) Higher loads may be applicable, if direction and magnitude of
individual loads are known, but these need written approval from
Flowserve

5) Pumps must be on rigid foundations and baseplates must be

fully grouted

6) Pump/baseplate should not used as pipe anchor. Expansion

joints must be properly tied.

7) The pump mounting bolt torques specified must be used to

prevent relative movement between the pump casing and
baseplate. (See section 6.6, Fastener torques.) The bolt
material must have a minimum yield strength of 600 N/mm

2

(87 000 lb/in.

2

)