Flowserve CPXVC User Manual

Page 8

Advertising
background image

CPXVC USER INSTRUCTIONS ENGLISH 26999930 03-11

Page 8 of 32

flowserve.com

Ensure the pump and relevant suction and discharge
pipeline system is totally filled with liquid at all times
during the pump operation, so that an explosive
atmosphere is prevented. In addition it is essential to
make sure that seal chambers, auxiliary shaft seal
systems and any heating and cooling systems are
properly filled.

If the operation of the system cannot avoid this
condition, fit an appropriate dry run protection device
(for example liquid detection or a power monitor).

To avoid potential hazards from fugitive emissions of
vapor or gas to atmosphere the surrounding area
must be well ventilated.

1.6.4.5 Preventing sparks

To prevent a potential hazard from mechanical

contact, the coupling guard must be non-sparking
and anti-static for Category 2.

To avoid the potential hazard from random induced
current generating a spark, the baseplate must be
properly grounded.

Avoid electrostatic charge: do not rub non-metallic

surfaces with a dry cloth; ensure cloth is damp.

For ATEX the coupling must be selected to comply
with 94/9/EC. Correct coupling alignment must be
maintained.

1.6.4.6 Preventing leakage

The pump must only be used to handle liquids

for which it has been approved to have the correct
corrosion resistance.

Avoid entrapment of liquid in the pump and associated
piping due to closing of suction and discharge valves,
which could cause dangerous excessive pressures to
occur if there is heat input to the liquid. This can occur if
the pump is stationary or running.

Bursting of liquid containing parts due to freezing
must be avoided by draining or protecting the pump
and ancillary systems.

Where there is the potential hazard of a loss of a seal
barrier fluid or external flush, the fluid must be monitored.

If leakage of liquid to atmosphere can result in a
hazard, install a liquid detection device

1.6.4.7 Maintenance to avoid the hazard

CORRECT MAINTENANCE IS REQUIRED TO

AVOID POTENTIAL HAZARDS WHICH GIVE A
RISK OF EXPLOSION

The responsibility for compliance with maintenance
instructions is with the plant operator.

To avoid potential explosion hazards during
maintenance, the tools, cleaning and painting
materials used must not give rise to sparking or
adversely affect the ambient conditions. Where there
is a risk from such tools or materials, maintenance
must be conducted in a safe area.

It is recommended that a maintenance plan and
schedule is adopted. (See section 6, Maintenance.)

1.7 Nameplate and safety labels


1.7.1

Nameplate

For details of nameplate, see the Declaration of
Conformity.
Where a unit is ATEX Group II Category
1 below the soleplate there is an additional ATEX
marking plate (see section 1.6.4.2 Marking).

1.7.2

Safety labels


Oil lubricated units only: