2.2 Handling
Boxes, crates, pallets or cartons may be unloaded
using fork lift vehicles or slings dependent on their
size and construction.
2.3 Lifting
A crane must be used for all pump
sets or components in excess of 25 kg (55 lb). Fully
trained personnel must carry out lifting, in
accordance with local regulations.
To avoid distortion, the pump unit should be
lifted by using lifting equipment certified to local
standards.
The pumps are generally very heavy therefore,
size/shape factors will have to be considered before
attempting to lift them. It is strongly recommended to
attempt lifting from a safe distance to prevent any
injury or loss of life. Consulting with experts is
recommended.
Pump heads may be shipped with the seal
housing installed. For ease of assembly and to
prevent damage, we recommend removing the
housing before putting the head on the pump.
Flowserve will not supply eyebolts neither
fixed nor separately with the pump. It is the
responsibility of the installer to arrange appropriate
hardware that can handle the weights and results in
safe and successful installation.
Before lifting the driver alone, refer to the
manufacturer’s instructions.
2.3.1
Lifting of fabricated discharge heads with
or without the pump
If the pump is supplied with a fabricated discharge
head use 2 point or 3 point method of lifting as shown
in the details provided in 2.3.1.1 & 2.3.1.2. This
method is applicable to the lifting of discharge heads
with or without the pump.
2.3.1.1
Two point lifting of fabricated discharge
head types TF, UF & HFH (with or
without pump attached)
Figure 2.1
50 mm (2in.) HOLE
FABRICATED WITH
2 POINT LIFTING
"L"
Fabricated heads with discharge size mm (in.)
100
(4)
150
(6)
200
(8)
250
(10)
300
(12)
Pin
Dia.
25
(1)
32
(1.25)
32
(1.25)
32
(1.25)
38
(1.5)
L
1070
(42)
1220
(48)
1220
(48)
1370
(54)
1370
(54)
“L” is approximate length
2.3.1.2
Three point lifting of fabricated
discharge head of type HFL (with or
without pump attached)
Figure 2.2
HFL STYLE FABRICATED
WITH 3 POINT LIFTING