9

6.12 Install the stationary face support assembly face

down onto the sleeve assembly as shown in Figure

18. Lightly lubricate the area where the stationary

face O-ring [13.1] contacts the stationary face

support [100].

6.13 Before installing any O-rings in either the inner

gland [11] or stationary face support assembly,

assemble the two by aligning the pins and the

pin slots. Mark both parts in line with a marker

or pencil, one on the inner gland [11] OD close

to the stationary face support OD and one on the

stationary face support [100]. This will provide an

alignment guide to the pins during assembly of the

seal.

6.14 Select stationary face support O-ring [13.1], stretch

slightly and lightly lubricate. Lightly lubricate the

area in the inner gland [11] where the O-ring

contacts. Install the O-ring into the inner gland [11]

as shown in Figure 19.

6.15 Install the inner gland [11] onto the sleeve

assembly. See Figure 20. During the installation,

ensure that the drive pins in the gland line up with

the slots in the stationary face support by aligning

the marks from step 6.13.

Caution: Do not rotate the inner gland during

installation. This may cause the springs [16] to

buckle. Verify the pins are aligned by exercising

the inner gland.

6.16 Select inner gland O-ring [18.1] and place it into

the O-ring groove located on the inner gland [11].

See Figure 21.

6.17 Select rotating face support O-ring [71], stretch

slightly and lightly lubricate. Install the O-ring into

the ID groove in the rotating face support [99]. See

Figure 22.

6.18 Align the flats on the rotating face support [99] with

the flats on the sleeve assembly. Push the rotating

face support down until it seats squarely against

the shoulder on the sleeve. See Figure 23.

Figure 18

Figure 19

Figure 20

Figure 21

Figure 22

Figure 23

Advertising