7 support systems – Flowserve SLM-6000 User Manual

Page 10

Advertising
background image

10

Remove Centering/Setting Plates Prior to Operation Figure 15

Centering/Setting plate shown in

the stored position for equipment

operation.

Centering/setting plate shown in the

installed position for shipping, seal

installation and maintenance.

A screwdriver is used to lever
the centering/setting plate out.

Centering Plate

API Plan 52 (ANSI Plan 7352) Figure 16

6.2 Remove the setting plate locking screws. With a screwdriver, pry the setting plates

clear of the gland and remove them. Keep the setting plates and locking screws with

seal at all times. See Figure 15.

7 Support Systems

7.1 For seal fitted with quench ports and lip seal (SLM-6000 QCD):

7.1.1 Connect clean, low-pressure water to the quench inlet. See Figure 6. Water

flow must be regulated to 1-2 liter/min (1/4-1/2 gpm) at 35 kPa (5 psi)

maximum.

7.1.2 Quench outlet should be connected to plant drain.

7.1.3 Quench water must flow at all times when pump is in operation.

7.2 For seal fitted with quench ports and basic end face seal (SLM-6100 with Plan 52):

7.2.1 Supply tank inlet should be located vertically 1 meter (3 feet) above centerline

of equipment shaft and the outlet horizontally within 1-2 meters (3-6 feet) of

seal quench inlet port. See Figure 16.

7.2.2 Connect lower supply tank outlet port to seal quench inlet port. See Figure 16.

7.2.3 Seal quench outlet port should be connected to upper supply tank inlet port.

See Figure 16.

Fill Connection

Supply Tank Assembly

(with Cooling Coil Option)

.500” OD minimum tubing

(.750” OD recommended)

Drain Connection

1-2 meters

(3-6 feet)

maximum

1 meter

(3 feet)

minimum

Secondary

Seal

Primary

Seal

Advertising
This manual is related to the following products: