5 dry-side (bearing-side) installation – Flowserve SLM-6000 User Manual

Page 7

Advertising
background image

7

Cartridge in Place (Wet Side) Figure 10

Slide Cartridge onto Shaft Figure 11

Push on Gland to Slide the

Seal Over the Shaft/Sleeve

Do Not Hammer or

Push on Seal Sleeve

Do Not Hammer or

Push on Seal Sleeve

Push on Flange/Gland to Slide

the Seal Over the Shaft/Sleeve

4.7 Insert the retaining screws through the rear face of the pump case and screw into the

seal gland. Tighten the retaining screws evenly to pull the seal into the pump case.

See Figure 10.

5 Dry-Side (Bearing-Side) Installation

The following steps describe installation of the seal cartridge mounted on the dry,

or bearing, side of the equipment case. If your cartridge is designed to mount on the wet,

or impeller, side of the equipment case, refer to section 4. If you have completed section 4,

skip to section 6.

5.1 With the seal clamp collar facing toward the bearing assembly, slide the complete

cartridge over the pump shaft/sleeve and push back toward the bearing housing.

See Figure 11.

Warning: Do not hammer on or push against the cartridge sleeve.