2 mw-200 seal installation – Flowserve MW-200 Series User Manual

Page 4

Advertising
background image

4

2 MW-200 Seal Installation

Tools

needed:

Tools provided:

Lubricant for O-rings and equipment shaft OD.

Tools not provided:

Wrenches to secure housing nuts or bolts

Allen wrenches for housing cap screws

Allen wrenches for setting devices and set screws

2.1 Install the seal adapter plate on the vessel flange if required.
2.2 Lightly lubricate the equipment shaft along the entire length the

gasket O-rings will contact the shaft. Use the lubricant provided if it

is compatible with the process fluid.

2.3 Secure the vessel flange O-ring in the gasket O-ring groove using

the lubricant provided if it is compatible with the process fluid.

2.4 Install the MW-200 seal onto the equipment shaft with the end

containing the setting devices toward the equipment drive end and

position the seal assembly onto the vessel flange. Use the lifting

eyes supplied to gently lower the canister assembly onto the

adapter plate. Do not bolt the canister seal assembly to the adapter

plate or vessel flange at this time. Care should be exercised when

passing the seal sleeve incorporating the sleeve packing O-rings

over any keyways or threads that may be present. Any steps or

shoulders on the equipment shaft should be beveled to prevent

damage (pinching and cutting) of these sleeve gasket O-rings

during installation.

2.5 Position the canister seal assembly so that the liquid barrier ports

and any optional bearing lubrication fittings are easily accessible.

Advertising
This manual is related to the following products: