3 liquid barrier supply, 4 mw-200 seal piping – Flowserve MW-200 Series User Manual

Page 5

Advertising
background image

5

2.6 Reinstall the shaft coupling and/or drive. Remove any shaft

holding or restraining clamps and complete adjustments so that

the shaft is in its final operating position.

2.7 Install and tighten the vessel flange studs or cap screws to

secure the canister seal assembly to the vessel flange or adapter

plate. Do not over tighten.

2.8 Tighten the set screws in the sleeve drive collar uniformly with an

Allen wrench.

2.9 Remove the setting devices. Save the setting devices and

attachment hardware for future use.

3 Liquid Barrier Supply

The MW-200 Seal design is engineered to operate with a liquid

barrier fluid supplied to the seal chamber at a consistent pressure

2 bar (25 psig) above the maximum vessel pressure. Cooling water

may be required to cool the seal chamber. The liquid barrier fluid must

be compatible with the process fluid. The liquid barrier fluid to be used,

maximum vessel pressure, shaft speed, temperature, equipment, and

shaft size must be specified when the seal is ordered. Do not attempt

to use this seal under other conditions without consulting Flowserve.

4 MW-200 Seal Piping

4.1 Install piping for the liquid barrier fluid to the canister taps.

A supply tank with a pressure source and pressure gauge are

recommended. Install cooling water piping to the canister cooling

coils if required. See Figure 2.

4.2 Bearings (optional) have been pre-lubricated during seal assembly.