1 precautions, 2 brief description – Flowserve Circpac HP User Manual

Page 2

Advertising
background image

2

1 Precautions

1.1 Please read these instructions carefully. Installation in accordance

with the following instructions will contribute to long, trouble-free life of

the Circpac HP.

1.2 For related control panels or other auxiliary equipment, separate

instructions are required.

1.3 The Circpac HP and related equipment must be transported and

stored in the unopened, original shipping container. Warehouse

storage must be clean and dry.

1.4 The ultimate user must ensure that personnel assigned to handle,

install, and operate the Circpac HP and related equipment are well

acquainted with the design and operating requirements of such

equipment. The manufacturer is not liable for damage incurred

through improper handling, installation or use.

2 Brief Description

2.1 The Circpac HP is an engineered, segmented circumferential gas seal

for gas compressors. Each seal is custom designed for a specific

application and should only be operated according to the limits of the

specific application.

2.2 The Circpac HP is delivered as a complete, ready-to-install cartridge

unit. Depending on the application, the cartridge may include a sleeve

(preferred).

2.3 Dynamic sealing occurs between the stationary circumferential ring

and the rotating sleeve/shaft where pressure breaks down across the

sealing surface. Static sealing occurs at gasket points and between

the stationary ring and stationary housing. The ring is designed to

contact the sleeve/shaft to minimize gas leakage.

2.4 Depending on the application, multiple ring configurations may be

used. Examples include: tandem for high pressure, double for zero

emissions, and bearing purge for oil containment. Proper piping,

control system design, and system operation are required for long-

term seal performance. If zero product emissions are desired, barrier

gas at a higher pressure than the product is required at all times.

2.5 Long-term seal performance is best attained if the following conditions

are sustained. Failure to comply with these conditions may result in

excessive gas consumption and/or product leakage to the

atmosphere.

2.5.1 Good equipment condition and consistent operation within the

equipment manufacturer’s specifications.

2.5.2 Perpendicular orientation between the shaft sleeve and the

equipment housing.

Advertising