4.10 Disengage setting plates and store separately.

4.11 Inspect equipment and driver alignment in accordance with coupling

and/or equipment manufacturer’s instructions.

5 Piping and Control System

5.1 Proper piping and control system installation are imperative to correct

seal operation. Piping ports are detailed on the mechanical seal

assembly drawing and clearly marked on the mechanical seal

housing. Installation and operating instructions specific to Flowserve

control panels are available separately and must be carefully

followed.

5.2 Piping connections may include combinations of the following

examples where multiple descriptions may apply to each port

connection.

• Double barrier – inject clean external gas between a pair of rings

at a pressure typically 0.3 – 0.7 bar (5-10 psi) above upstream ring

pressure for zero emissions.

• Tandem purge – inject clean external gas between a pair of rings

at a pressure lower than upstream ring pressure and vent from the

same pair to a low pressure flare.

• Inboard gas purge – inject clean external gas or filtered product

gas between the first pair of rings at slightly higher pressure than

product (typically 0.2 - 0.3 bar [3-5 psi] differential) to maintain

clean inboard rings.

• Bearing purge – inject clean external gas before bearing ring at

higher pressure than bearing cavity (typically 0.2 – 0.3 bar

[3-5 psi] differential) for the purpose of restricting oil ingression,

typically vented through a dedicated port.

• Sensing/reference – connection to the reference port of a

differential pressure regulator to maintain constant purge or barrier

pressure differential across the downstream ring.

• Vent – connection to low pressure flare system or other approved

destination where vent pressure is the lowest pressure piping

connection.

• Drain – disposal of liquids including condensate or bearing oil

and for maintenance procedures such as in-place cleaning.

• Tandem sensing – connection to a pressure gage or transducer

to monitor the pressure between ring stages as a measure of seal

performance.