Flow Control Division

Section 1.0

1. Normal procedures for field replacement of port seals or

sleeves are to be followed. Refer to V-A, steps 1-5, and

V-B, steps 1-8.

2. The fireseal top seal assembly differs from the standard

Marathon-Mach 1 top seal and is completed per the

following instructions.

3. The plug stem should be checked for nicks before

installing the PFA diaphragm. Nicks on this surface could

result in scratches on the lip of the diaphragm. The PFA

diaphragm is to be flared on the diaphragm guide (Part

Series BY86272A) just enough to slip over the plug stem.

FIGURE VI-1

4. The PFA diaphragm is turned over and placed over the

plug stem with the lip down using the diaphragm guide.

FIGURE VI-2

5. Remove the diaphragm guide. The metal diaphragm is

placed over the plug stem just far enough to enlarge the

ID to conform to the plug stem and then removed.

6. The metal diaphragm is removed from and replaced on

the plug stem with the ID lip down.

7. The Grafoil packing ring is placed over the stem.

FIGURE VI-3

SECTION VI
ASSEMBLY SPECIFICATIONS - FIRESEAL VALVES 1"- 6" MARATHON-MACH 1

FIGURE VI-1

FIGURE VI-3

FIGURE VI-2

Place PFA diaphragm over plug

stem with lip down.

If damaged, the

plug taper and

1” in length of

stem must be

repolished to a

surface finish of

16 on the taper

and stem.