Flowserve Marathon-Mach 1 User Manual

Page 6

Advertising
background image

6

Flow Control Division

Section 1.0

SECTION IV

TABLE II

NUTS

HN - Finished Heavy Hex Nut

XN - Finished Hex Nut

HXN - Regular Heavy Hex Nut

Dimension per ANSI B18.2.2

Alloy identification stamp is required on each piece.

Certification required.

8 -

304 Stainless Steel per ASTM A194, Grade 8

8M - 316 Stainless Steel per ASTM A194, Grade 8M

2H - ASTM A194, Grade 2H

2HM - ASTM A194, Grade 2HM

7M - ASTM A194, Grade 7M, 100% hardness tested

7MT - ASTM A194, Grade 7M, 100% hardness tested, Teflon

®

coated, Dupont SP11C, Type B - Color blue or green

M -

Monel (UNS N04400), ASTM B164, Class A or B, QQN-281, Class B

HB - Hastelloy B (UNS 10665), ASTM B335

HC - Hastelloy C276 (UNS N10276), ASTM B574

I625 - Inconel 625 (UNS N06625), ASTM B446

I718 - Incoloy 718, AMS 5596B

I825 - Incoloy 825 (UNS N08825), ASTM B425

L7 -

Chromium-Molybdenum Alloy Steel per ASTM A194, Grade 7

L7M - Chromium-Molybdenum Alloy Steel per ASTM A194, Grade 7M, 235 BHN Max, ASTM A320, Section 9

MKH - Monel K-500, Cold drawn and aged hardened, QQN-286 and ASTM F467

8F -

303 Stainless Steel per ASTM A194, Grade 8F

2HYC - ASTM A194, Grade 2H, Yellow Zinc Dichromate Plated

SECTION V
A. VALVE ASSEMBLY 1"- 6" MARATHON-MACH 1 WITH PORT SEALS

NOTE: Part number reference is shown in Figure II-1.

1. Mount body (Part 1) on arbor press or table vise holding

one flange.

2. Place port seals (Part 2) in position into body. Align port

seal ports with body ports. (See Figure V-A-1)

FIGURE V-A-1

3. Place the plug (Part 4) into the port seals in the closed

position.

4. Push the plug (still in the closed position) downward, using

the arbor press, c-clamp or other suitable means, until the

top of the plug taper is 1/16" above the top port seal

surface. Allow the plug to remain in this position for the

time listed in Table V-A-I, Port Seal Sizing Times.

TABLE V-A-I

PORT SEAL SIZING TIMES
VALVE SIZES

1" - 3"

4" - 6"

TIME (min) 5 8

5. Remove the plug.

6. Ensure the plug stem is free of any nicks or gouges.

If damaged, the plug taper and 1" of the lower part of the

stem must be re-polished to a surface finish of 16.