10. Technical data

Common data

Repeatability

<0,3%

Air delivery Supply at 600 kPa

125 nl/min

Air delivery Exhaust at 600 kPa

125 nl/min

Air supply pressure range

140-600kPa

Gain % / % acc. to ISA S75

5 to 30 %/%

Temperature range

-40

°C to +85°C

Temperature sensitivity

< 0.4% per 10

°C

Stroke length

6 - 60 mm, option 3 mm

Other data

P3

Linearity

<

±1%

Hysteresis + Deadband

<0.5%

Deadband

<0.15%

Air consumption (depending on gain setting)

2-8 nl/min

Supply pressure sensitivity

<0.20%

Input signal

0.2 - 1 bar (3 - 15 psi)

EP3

Linearity

<

±1.5%

Hysteresis + Deadband

<1%

Deadband

<0.2%

Air consumption (depending on gain setting)

4-10 nl/min

Supply pressure sensitivity

<0.3%

Input signal

4 - 20 mA

EP3EX

Linearity

<

±1.5%

Hysteresis + Deadband

<1%

Deadband

<0.2%

Air consumption (depending on gain setting)

4-10 nl/min

Supply pressure sensitivity

<0.3%

Input signal

4 - 20 mA