Torex TX VLEEIM4143-02 09.10

9

4.

Connect the compressed air supply to the

actuator. (Applies to pneumatic actuators.)

5.

Adjust the end position stop until the actuator

has turned the valve disc to the sealing position.

This sealing position varies from valve to valve,

and the dimension is specified on the valve body

adjacent to the arrow showing the direction of

flow. See dimension ”A” in Fig. 4 in section 9.4.

6.

General

The actuator may be fitted either in line with the

connected pipes or transversely to them. An

intermediate plate is necessary for mounting the

actuator in line with the pipework.

N.B. The direction of closure must always be clock wise,

as viewed from the actuator.

Before fitting the actuator, it is important to ensure that the

actuator fits the stem. First try without keys, to check that

the drive slips easily onto the stem. Also check that the keys

are easy to fit and match the keyways in the stem. Grease

the actuator stem entry.

Take care to ensure that the end position stops on the

actuator are correctly set and locked. If the end position stop

for the closed position is incorrectly set, the valve disc may

overtravel, which could damage the sealing elements.