Flowserve 020000 Series Kämmer Split Body Valves User Manual

Page 5

Advertising
background image

5

Flow Control Division

Kammer Control Valves

6

REMOVE AND INSTALL ACTUATOR

General Information

We recommend separating the actuator from

the valve during all repair work. However, many

maintenance and adjusting operations can be carried

out in an installed condition.

6.1

Remove series 4 actuator

(see Fig 1 + 2)

For series 2 actuator see 6.3

For actuators with spring-to-close, go to 6.1.1

For actuators with spring-to-open, go to 6.1.2

6.1.1 Shut off air supply.

WARNING: Depressurise the line to atmospheric

pressure and drain all fluids from the valve before

working on the actuator. Failure to do so can cause
serious injury.

6.1.2 Remove cap and nameplate. Tighten zero adjusting

nut until it just touches the surface of the spring

housing. This relieves the plug from actuator spring

pressure. If the actuator is fitted with a handwheel

this can be used to relieve the plug from actuator

spring pressure.

3.1.3 Using a wrench, secure the actuator stem against

turning and using a second wrench loosen the stem

locknuts. If the actuator is fitted with a coupling

refer to the procedure described in the maintenance

instructions for the I/P actuator.

CAUTION: The actuator stem must not be rotated,

as this will cause damage to the diaphragm.

6.1.4 Loosen gland and clamp nuts.
6.1.5 Secure plug stem against turning and unscrew actua-

tor from plug stem by rotating counter-clockwise.

CAUTION: Ensure that the plug assembly is not

rotated with the plug seated. This may cause ir-

reparable damage to the seating faces.

6.1.5 Remove actuator and remove at the same time

locknut, travel indicator disc, gland nut and clamp

nut.

3.2

Install series 3 actuator

Information:

Before the actuator is installed, it must be

calibrated according to section 3 of the instructions

„Pneumatic and Electro-pneumatic Actuators“.

All worn or damaged parts must be re-

placed. Reusable parts must be clean.

6.2.1 Position actuator with clamp nut, gland nut, locknuts

and travel indicator disc on the valve.

6.2.2 Only for „spring-to-close“ actuators:

Screw actuator onto plug stem by rotating clockwise,

until the yoke plate just touches the valve housing

and the actuator is aligned forward. If the actuator

is fitted with a coupling refer to the procedure de-

scribed in the maintenance instructions for the I/P

actuator.

CAUTION: Ensure that the plug assembly is not rotated

with the plug seated. This may cause irreparable dam-

age to the seating faces.

Only for „spring-to-open“ actuators:

Lift plug stem and screw it into the lower coupling half

until the distance between „plug in seat“ and „plug

raised“ approximately corresponds to the specified

stroke.

6.2.3 Tighten clamp nut and gland nut.
6.2.4 Adjust seat tightness by screwing/unscrewing the plug

stem in/out of the actuator stem.

CAUTION: Ensure that the plug assembly is not rotated

with the plug seated. This may cause irreparable dam-

age to the seating faces. Open valve, make adjustment,

close valve and check for leaks. If the valve is fitted

with a bellows seal the plug stem may NOT be rotated

at all. In the case of a bellows seal adjustments are

made with the coupling.

6.2.5 After adjusting, secure the locknuts and the travel

indicator disc lying between them against actuator

stem and align the travel indicator on the yoke rod.

6.3

Remove series 2 actuator

(see Fig. 1a)

For series 4 actuator see 6.1

6.3.1 Shut off air supply.

WARNING: Depressurise the line to atmospheric

pressure and drain all fluids from the valve before

working on the actuator. Failure to do so can cause

serious injury.

6.3.2 Disconnect all tubing.
6.3.3 Remove 2 screws and remove coupling.
6.3.4 Remove yoke rod retaining nuts and lift actuator

assembly from the valve.

6.3.5 Remove coupling insert and it’s locknut from plug

stem.

CAUTION: Ensure that the plug assembly is not
rotated with the plug seated. This may cause
irreparable damage to the seating faces.

6.4

Install series 2 actuator

(see Fig. 1a)

The actuator stem must be fully extended:

Actuators with air-to-open action must be fully

vented. Actuators with air-to-close action apply

supply pressure.

Manually depress the plug stem to ensure the plug is

fully seated.

6.4.1 Screw coupling insert locknut and coupling insert as

far as possible onto plug stem.

6.4.2 Place the actuator assembly on the valve engaging the

yoke rod threads in the lower yoke plate and ensuring

the actuator faces in the correct direction.

STOP!

STOP!

Advertising