Figure 30: mounting interface dimensions – Flowserve LPS Pneumatic Heavy-Duty Actuator Series User Manual

Page 30

Advertising
background image

LPS Series Heavy-Duty Actuators FCD LFENIM0001-02-AQ – 5/15

30

Figure 30: Mounting Interface Dimensions

"U"

IMPORTANT: threaded through

holes. During studs assembly use

Loctite 542 (or equivalent) in order to

obtain a perfect seal.

F

"E"

"G"

"H"

I

L

G H7

H e8

F

E

+

-

0,1

0,1

I

(max keyway length)

IMPORTANT: threaded through

holes. During studs assembly

use Loctite 542 (or equivalent)

in order to obtain a perfect

seal.

Stud threaded length must not

excede "F" + 3 mm.

L

DETAIL W

ØG H7

ØH e8

90°

30°

ATTENTION: The angular positions

of the holes are rotated with respect

to indications of ISO 5211.

The holes are on centerlines.

1

4 Holes Flange

12 Holes Flange

45°

C

"A"

B

n x

"D"

viste da cui sono stati ricavati gli sketches nel disegno

Notes:

- Holes in-line wit axis of actuator (NOt off-center)

- Flange torque different from ISO 5211 specification

ØA D8

C

+

+

0,20

0,10

n x

D

B D10

P ±0,05

G 3/4

45°

IMPORTANT: Position of the

keyways with actuator at 0°

degree (closed position).

Bottom View

(from "U")

W

8 Holes Flange

FLOW LINE

LPS/LHS Series Coupling Dimensions

Model

ISO 5211 Flange

Interface (reference)

ØA

B

C

Number of holes

n

Hole Diameter

ØD

P.C.D.

[mm(inch)]

E

F

ØG

ØH

I

L

P

LPS/LHS 15

F16

65

10

70.6

4

M20

165 (6,50)

18

86

78

161

8

155

LPS/LHS 20

F25

86

12

91.6

8

M16

254 (10)

16

130

112

178

4.5

205

LPS/LHS 25

F30

100

18

108.8

8

M20

298 (11,73)

18

150

133

201

6

230

LPS/LHS 30

F35

130

28

138.6

8

M30

356 (14,02)

28

168

152

261

10

305

LPS/LHS 35

F40

150

36

166.8

8

M36

406 (15,98)

33

199

185

323

9

405

LPS/LHS 40

F48

185

45

205.8

12

M36

483 (19,02)

38

244

230

338

10

450