Flowserve L120-190 through L120-2000 User Manual

Page 17

Advertising
background image

17

Limitorque

®

L120-190 through L120-2000 FCD LMENIM1203-00 – 10/11

flowserve.com

Table 5.4 – Maximum Drive Sleeve Turns

Limit Switch Gearing

PIC Gearing

Actuator Size

W.G. Ratio

4-Gear

5-Gear

PIC or R/I (270)

RVDT(90)

L120-190

13.3:1

3110

31100

13706

4569

33:1

1250

12500

5521

1837

60:1

690

6900

3037

1012

85:1

N/A

N/A

N/A

N/A

L120-420

10.33:1

N/A

N/A

N/A

N/A

16:1

3300

33000

11405

3797

41:1

1280

12800

4445

1481

57:1

910

9100

3195

1065

80:1

N/A

N/A

N/A

N/A

L120-800

12.67:1

N/A

N/A

N/A

N/A

19:1

2850

28500

9586

3195

49:1

1050

10500

3720

1240

58:1

N/A

N/A

N/A

N/A

86:1

N/A

N/A

N/A

N/A

L120-2000

43:1

1210

12100

4234

1413

71:1

740

7400

2566

855

Figure 5.4 – Geared Limit Switch

Set the limit switch as shown on the following page. All item letters and piece numbers refer to Figure 5.5.