Table 5.4 – Maximum Drive Sleeve Turns
Limit Switch Gearing
PIC Gearing
Actuator Size
W.G. Ratio
4-Gear
5-Gear
PIC or R/I (270)
RVDT(90)
L120-190
13.3:1
3110
31100
13706
4569
33:1
1250
12500
5521
1837
60:1
690
6900
3037
1012
85:1
N/A
N/A
N/A
N/A
L120-420
10.33:1
N/A
N/A
N/A
N/A
16:1
3300
33000
11405
3797
41:1
1280
12800
4445
1481
57:1
910
9100
3195
1065
80:1
N/A
N/A
N/A
N/A
L120-800
12.67:1
N/A
N/A
N/A
N/A
19:1
2850
28500
9586
3195
49:1
1050
10500
3720
1240
58:1
N/A
N/A
N/A
N/A
86:1
N/A
N/A
N/A
N/A
L120-2000
43:1
1210
12100
4234
1413
71:1
740
7400
2566
855
Figure 5.4 – Geared Limit Switch