Flowserve LY Series Limitorque User Manual

Page 16

Advertising
background image

Limitorque LY Series: LY 1001, LY 2001 and LY 3001 FCD LMENIM1501-00 – 11/11

16

Table 5.2 – LY Actuator/Mounting Base Tap Sizes

Unit Type

and Size

Qty

Tap Size

English

Metric

LY 1001

8

3/8-16 x

0.71 deep

M10 x 1.5 mm x 25 mm deep

(Complies with F10 ISO

mounting flange criteria)

LY 2001/3001

8

5/8-11 x

1.26 deep

M16 x 2 mm x 35 mm deep

(Complies with F10 ISO

mounting flange criteria)

NOTE: Flowserve has supplied eight taps for the LY 1001, LY 2001, and LY 3001 in English/Metric
units to provide flexibility in mounting arrangements. A minimum of four securing bolts is required to
properly secure and retain torque reaction on these units.

c

WARNING: HAZARDOUS VOLTAGE. No electrical power should be connected until all wiring
and limit switch adjustments have been completed. Once power is supplied to unit, exercise
caution if cover is not installed.

4. Remove the Control Cover (piece #3) and Conduit Pipe Plugs (piece #144).

Figure 5.4 – Removing Control Cover and Conduit Pipe Plugs

Table 5.3 – Control Cover and Conduit Pipe Plug Hardware

Unit Type

Control Cover

Conduit Pipe Plug

Quantity

Size

Quantity

Size

LY 1001

(WP & XP)

6

M8 x 40 mm

2

1" NPT Socket

Hex Head

LY 2001/3001

8

M12 x 50 mm (WP)

M12 x 55 mm (XP)

2

1" NPT Socket

Hex Head

L i m

i t o

r q u

e

#3 Control Cover

#144 Conduit Pipe Plugs

Advertising