Remove Declutch Assembly

19. Remove Roll Pin (piece #121) and remove Declutch Lever (piece #45).

20. Push the Declutch Assembly (piece #46, 123, 44, and 55 [two pieces]) up through the Housing and

remove. Remove the Declutch Return Spring (piece #47).

21. Remove O-Ring (piece #138) from the Housing.

Remove Input Worm Gear

22. Remove the Retaining Drive Ring (piece #114).

23. Remove Input Worm Gear (piece #18) from the Ball Bearing (piece #24).

7.3.2 LY 1001 Reassembly

c

WARNING: HAZARDOUS VOLTAGE. Turn off all power before reassembling your LY actuator.

All piece numbers refer to Figures 6.5, 6.6, and 6.7.

Install Input Worm Gear

1. Install Input Worm Gear (piece #18).

2. Install External Retaining Drive Ring (piece #114) on Input Worm Gear.

Install Declutch Assembly

3. Install Declutch Return Spring (piece #47), making sure one end of Spring is secured behind the

Rib of the actuator housing and the other end is secured behind the bottom Declutch Fork of the
Declutch Fork Assembly.

Figure 7.1 – LY 1001 Declutch Return Spring Installation Position

6301 .

6301 .

Rib

Bottom

Declutch

Fork

LY 1001 End View

#47 Declutch

Return Spring

Rib

LY 1001 Top View