Function

During start-up of the plant the Duo stainless steel plates are flat. The service pressure acts in the opening

direction, the valve is completely open. As the condensate temperature rises, the plates deflect, drawing

the stage nozzle towards the closed position. As the condensate temperature sinks, the deflection of the

Duo stainless steel plates decreases and the steam trap opens at the adjusted opening temperature.
The thermostatic and spring characteristics of the stack of plates are balanced such that condensate is

always discharged at a given undercooling temperature.
The trap provides automatic air-venting at start-up and during operation. BK 27N can also be used for

thermal air-venting in steam systems.

Explanatory Notes

Scope of supply

BK 27N:

 Steam trap BK 27N

 Installation manual

Description

Thermostatic steam trap with corrosion-resistant thermostatic element (Duo stainless steel bimetallic

regulator, externally adjustable) unaffected by waterhammer. With internal Y-type strainer, integrated

non-return valve and asbestos-free cover gasket (graphite). Installation in any position.
The default factory setting allows the steam trap to discharge condensate with virtually no banking-up. For

more undercooling the settings of the installed, depressurized steam trap can be modified externally.

BK 27N:

For installation in horizontal and vertical pipes.