Flowserve NRS 2-4 User Manual

Page 7

Advertising
background image

7

Technical Data

Supply voltage
24 V DC

Power consumption
2 VA

Output – Measuring circuit
12 V DC (supply voltage going to level electrode)
30 mA

Input – Measuring circuit
1 – 10 V DC (measuring voltage coming from level electrode)

Output – Control circuit
2 volt-free relay contacts
Max. contact rating with switching voltages of 24 / 115 / 230 V AC: 4 A resistive,
0.75 A inductive at cos

ϕ

0.5.

Max. contact rating with switching voltage 24 V DC: 4 A
Service life of relay: 30 x 10

6

switching cycles

2 optocouples (npn), short-circuit protected due to inherent current limiting
characteristics
Max. ratings: 70 V, 10 mA

Indicators and adjustors
1 green LED

OPERATION

, 1 red LED

HIGH

LEVEL

, 1 yellow LED

DEFECTIVE

ELECTRODE

, 1

yellow LED

MALFUNCTION

IN

CABLE

Protection
IP 10 to DIN 40050

Max. admissible ambient temperature
0 °C to + 70 °C

Case
19" slide-in unit with front panel to DIN 41494 part 5 and rear 32 way Euro card
connector to DIN 41612 for installation into 19" magazine
Front panel: aluminium

Weight
Approx. 0.6 kg

Advertising