Technical data – Flowserve TRG 5-6x User Manual

Page 7

Advertising
background image

7

Technical Data

– continued –

TRG 5-63, TRG 5-64, TRG 5-65, TRG 5-66, TRG 5-67 and TRG 5-68

– continued –

Materials
TRG 5-63, TRG 5-64
Protection tube 1.4571, X6 CrNiMoTi 17 122

TRG 5-65, TRG 5-66
Welding sleeve 1.7335

TRG 5-67, TRG 5-68
Welding sleeve 1.4961

Ambient temperature at terminal box
Max. 70°C

Protection
IP 66 to DIN EN 60529

Cable entry / Wiring
EMC cable gland with integrated cable gland M 20x1.5

Weight
TRG 5-63, TRG 5-64
Approx. 0.5 kg

TRG 5-65, TRG 5-66
Approx. 0.6 kg

TRG 5-67, TRG 5-68
Approx. 1 kg

Tolerances of the precision resistor acc ording to EN 60751

* Class A and B, admissible tolerances of the precision resistor

-200

Temperature in °C

-100

0

100 200 300 400 500 600 700 800

A

d

mis

sib

le

d

evi

at

io

n

in

:

A

d

mis

sib

le

d

evi

at

io

n

in

°C

±2

± 1.5

±1

± 0.5

±4

± 3

± 2

±1

Cl

as

s B

°C

Clas

s A

°C

Class A :

Clas

s B :

Advertising