4

Maintenance

– continued –

Torques for tightening

All torques refer to a room temperature of 0 °C.

. Observe the danger note on page 4!
. Unscrew body screws

A and take the cover E off the body I, Fig. 2

. Unscrew hand purging knob

B.

4. Unscrew valve insert

F.

5. Unscrew sealing plug

L and strainer J.

6. Clean strainer, sealing plug and gasket surfaces.
7. Clean seating surfaces of body and cover.
8. Apply heat-resistant lubricant to all threads, seating surfaces of the valve insert and of the cover

(e. g. WINIX

®

50).

9. Replace gasket

H only if there are visual signs of damage.

0. Replace gasket

K if there are visual signs of damage.

. Mount new hand purging knob

F and tighten with a torque of 40 Nm.

. Mount new valve insert

B and tighten with a torque of 90 Nm.

. Put cover on valve body. Tighten body screws evenly with

25 Nm.

4. Mount sealing plug

L together with strainer J and tighten with 120 Nm.

Replace hand purging knob and valve insert

Tools

Spanner 6 mm A.F., DIN , Form B

Spanner 9 mm A.F., DIN , Form B

Spanner  mm A.F., DIN , Form B

Torque spanner 0-0 Nm, DIN ISO 6789

WINIX

®

50 is a registered trademark of WINIX GmbH, Norderstedt

Item

Designation

Torque [Nm]

F

Valve insert

0

90

B

Hand purging knob

0

40

A

Body screws

0

5

L

Sealing plug

0