Explanatory Notes

System description

Scope of supply

AK 45
 Condensate drain valve AK 45

 Installation manual

The AK 45 automatically discharges condensed water from steam systems during start-up, until the

pressure in the system has reached the adjusted valve closing pressure.

At shut-down or when the pressure falls below the closing pressure the valve opens and accumulated

condensate is automatically discharged.

When there is no pressure in the system the drain valve is held in the open position by the integrated

spring. As soon as the service pressure has reached the closing pressure to which the AK 45 has been

adjusted, the valve closes (by the differential pressure acting on the valve cone against the force of the

spring). When the pressure drops below the closing pressure, the AK 45 opens by spring force.
A hand purging knob is provided, so that the AK 45 can be briefly opened by hand with the system

under pressure to clear any deposits from the valve seat area.
The AK 45 is adjusted at our works to close at a differential pressure of 0.8 barg ( psig).
The AK 45 is provided with a built-in strainer.