GAI-Tronics 293-101 Externally Powered ADA-Compliant Emergency Phones User Manual
Page 3
Pub. 42004-378C
E
XTERNALLY
P
OWERED
ADA-C
OMPLIANT
E
MERGENCY
P
HONES
P
AGE
2
of 28
\\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-378c.doc
08/06
The GAI-Tronics emergency phone product line provides the flexibility to address a diverse range of
applications. A wide variety of functions can be achieved by altering the configuration data stored in the
phone’s non-volatile memory. These configuration options include:
• Pre-programmed auto-dial telephone numbers
• Call termination method (automatic or manual)
• Maximum call duration
• Answering options
Each of the above emergency phones require a “Class 2” 12 V dc regulated power supply (included) and
can be connected to any of the following:
• Central Office (CO) line to the Public Switched Telephone Network (PSTN)
• 24 V dc or 48 V dc analog station port of Private Branch Exchange (PBX), Private Automatic Branch
Exchange (PABX) or KSU.
Connection may not be made to pay phone extensions or shared service (party) lines.
N
OTE
: Each telephone requires a dedicated power supply. Multiple telephones cannot be
connected to a single power supply. The power supply must provide galvanic isolation between its
input and its 12 V dc output. For dc-to-dc applications, galvanic isolation is required. Galvanic
isolation (separation) is achieved by using a transformer or opto-coupler.