Maintenance

If the module requires service, contact your Regional Service Center for a return authorization number
(RA#). The module should be shipped prepaid to GAI-Tronics with a return authorization number and a
purchase order number. If the module is under warranty, repairs or a replacement will be made in
accordance with GAI-Tronics’ warranty policy. Please include a written explanation of all defects to
assist our technicians in their troubleshooting efforts.

Call 800-492-1212 inside the USA or 610-777-1374 outside the USA for help identifying the Regional
Service Center closest to you.

Troubleshooting

Problem Solution

SmartSeries station faults are
present in the secondary system.

• Verify 12 V dc power is applied to the module.
• Verify CPU PCBA address is set to FF.
• Verify cables are properly inserted into connectors J1, J2, J3.
• Ensure J1 pins of CPU PCBA are correctly inserted into J4 of

lower relay switching PCBA.

SmartSeries stations squeal
when party line 1 or 2 are
accessed.

• Verify connectors J1, J2, J3 are properly inserted. If

disconnected, the page, and party lines 1 and 2 will be
unloaded resulting in oscillation of the SmartSeries handset
amplifier.

Module LEDs do not illuminate
and relays do not switch when
input control is provided.

• Verify 12 V dc (-) is being switched to the PRI

and/or SEC

inputs at JTB4

Module still does not function after
all checks described in this section.

Contact GAI-Tronics service for repair or replacement of the
module.