Troubleshooting

The following table is provided to aid qualified service personnel in troubleshooting problems with the
ICS Page/Party

®

subset.

Problem Potential

Cause

Subset is not functional.

 Verify DB25 Interconnect cable is properly terminated between

the subset and remote amplifier.

 Refer to general troubleshooting section in ICS Page/Party

®

Remote Handset/Speaker Amplifier manual for adjustments and
settings that affect ICS subset operation.

Specifications

Handset
Microphone ........................................................................................................... Dynamic, noise-canceling
Receiver .................................................................................................... Dynamic, hearing aid compatible
Cord ........................................................................................................... Retractile, 6-foot extended, PVC
Material ................................................................................................................................................... ABS
External control .............................................................................................. Push-to-page handset pressbar

Subset Specifications
Construction/finish ..................................................... 16-gauge cold-rolled steel/safety orange powder coat
Mounting ................................... Flush-mount or similar location; four 0.25-inch (6.3 mm) mounting holes
Cutout dimensions ................................................... 5.00 W

 4.88 H  2.6 D inches (127  124  66 mm)

Front panel dimensions ........................................................... 6.00 H

 6.00 W inches (152.4  152.4 mm)

Shipping weight .................................................................................................................. 4.75 lbs. (2.2 kg)
Net weight ........................................................................................................................... 2.75 lbs. (1.2 kg)

Environmental

Temperature range (operation and storage) ............................................ −22º F to 158º F (−30º C to 70º C)
Humidity ...................................................................................................................... 95% non-condensing

Approvals

NRTL certified for use in US and Canada ............................................................................. UL/CSA 60950
CE Mark

Advertising