Installation, Important safety instructions, Mounting the enclosure – GAI-Tronics 370-301 Dual Channel 600-Ohm to 33-Ohm Converter User Manual

Page 2

Advertising
background image

Pub. 42004-431B

370-301 Dual Channel 600 to 30-Ohm Converter

Page

2 of 9

f:\standard ioms - current release\42004 instr. manuals\42004-431b.doc
02/15

Installation

Important Safety Instructions

1. Read, follow, and retain instructions – All safety and operating instructions should be read and

followed before operating the unit. Retain instructions for future reference.

2. Heed warnings – Adhere to all warnings of the unit and in the operating instructions.

3. Attachments - Attachments not recommended by the product manufacturer should not be used, as

they may cause hazards.

4. Servicing – Do not attempt to service this unit by yourself. Opening or removing covers may expose

you to dangerous voltage or other hazards. Refer all servicing to qualified service personnel.

5. This permanently connected apparatus must have a UL Listed 15-amp circuit breaker incorporated in

the electrical installation of the building.

USA and Canada Consult the National Electrical Code (NFPA 70), Canadian Standards Association
(CSA 22.1), and local codes for specific requirements regarding your installation. Class 2 circuit wiring
must be performed in accordance with NEC 725.55.

WARNING

In 24 V dc systems: Under NO condition should this equipment be operated

from a battery charger without the batteries connected.

In 24 V dc systems, most chargers have an unloaded output of 35 to 45 volts that can quickly damage the
equipment designed for nominal 24 volts. The maximum battery voltage should never exceed the
maximum specified input voltage.

Mounting the Enclosure

N

OTE

: The enclosure is intended for indoor use only.

Mount the enclosure using the four 0.312-inch (8 mm) diameter holes located on the mounting flanges
with ¼-inch (M6) hardware. The 370-301 is not supplied with conduit or cable openings.

Remove the front panel and drill or punch entry openings in the rear section of the enclosure

Refer to Figure 2 for the suggested locations. There must be a minimum of ½ inch (13 mm) of material
between entry holes. The station is suitable for top or bottom entry per Figure 2. However, GAI-Tronics
recommends bottom entry only wherever possible.

The standard orientation shown in Figure 2 locates the power supply housing in the upper left corner.
The orientation of the enclosure can be rotated 180º to allow clear access to the top.

The 69856-xxx PCBA can then be rotated for correct orientation.

For specific details including mounting hole dimensions, refer to Figure 2. When mounting the enclosure,
use caution to avoid damaging the internal components.

Advertising