Settings & adjustments, Opening the station, Jumper settings – GAI-Tronics 370-301 Dual Channel 600-Ohm to 33-Ohm Converter User Manual

Page 7: Settings and adjustments

Advertising
background image

Pub. 42004-431B

370-301 Dual Channel 600 to 30-Ohm Converter

Page

7 of 9

f:\standard ioms - current release\42004 instr. manuals\42004-431b.doc
02/15

Table 6. 33-Ohm Connections Channel 2, P12

Pin

Number


Pin Name


Function

1

NC 33-ohm active

Normally closed connection of 33-ohm output VOX detection.

2

COM 33-ohm active

Common connection of 33-ohm output VOX detection.

3

NO 33-ohm active

Normally open connection of 33-ohm output VOX detection.

4

GND

Ground reference for field wiring.

5

L1 33-ohm audio

Bi-directional audio for 33-ohm interface

6

L2 33-ohm audio

Bi-directional audio for 33-ohm interface

Settings and Adjustments

Opening the Station

Remove the four screws from the front panel and place the front panel to the side.

Jumper Settings

Channel 1: 33-Ohm Activation P3 - Install the jumper in the ACT (default) position to enable the 33-
ohm audio output. Install the jumper in the NON position to disable the 33-ohm audio output.

Channel 1: 33-Ohm Termination P8 - The Page/Party

®

line can be terminated to 33 ohms as required

by the Page/Party

®

system. Install the jumper in the TERM position to terminate the line. Install the

jumper in the NON (default) position to leave the line unterminated. For the unterminated position, a
line balance assembly is needed in the system.

Channel 1: 600-Ohm Activation P7 - Install the jumper in the ACT (default) position to enable the
600-ohm audio output. Install the jumper in the NON position to disable the 600-ohm audio output.

Channel 2: 33-Ohm Activation P9 - Install the jumper in the ACT (default) position to enable the
33-ohm audio output. Install the jumper in the NON position to disable the 33-ohm audio output.

Channel 2: 33-Ohm Termination P14 - The Page/Party

®

line can be terminated to 33 ohms as required

by the Page/Party

®

system. Install the jumper in the TERM position to terminate the line. Install the

jumper in the NON (default) position to leave the line unterminated. For the unterminated position, a
line balance assembly is needed in the system.

Channel 2: 600-Ohm Activation P13 - Install the jumper in the ACT (default) position to enable the
600-ohm audio output. Install the jumper in the NON position to disable the 600-ohm audio output.

Advertising