Control output connections – GAI-Tronics 10959-908 Rack-Mount Audio Messenger Interfaces User Manual

Page 11

Advertising
background image

Pub. 42004-487A

M

ODEL

10959-906

&

10959-908

R

ACK

-M

OUNT

A

UDIO

M

ESSENGER

I

NTERFACES

P

AGE

9 of 18

f:\standard ioms - current release\42004 instr. manuals\42004-487a.doc
01/14

Table 1. Audio Assignment

Termination PCBA

Label

Internal Terminal

Pin-Out

Function or ACT Description

600-ohm L1

TB3-1

600-ohm audio pair to distribution amplifier cabinet,
Stanchion Broadcast electronics module, Addressable
Amplified Speaker, or other 600-ohm compatible devices.

600-ohm L2

TB3-2

AUDBUS2 L1

TB3-3

No connection

AUDBUS2 L2

TB3-4

AUDBUS1 L1

TB3-5

No connection

AUDBUS1 L2

TB3-6

PGND TB3-7

No

connection

RS485 INT GND

TB3-8

No connection

RS485 INT− TB3-9

RS485 INT+

TB3-10

Control Output Connections

Terminal block TB4, labeled

SYSTEM

, is located on the Termination PCBA. It provides connection for a

contact closure output to activate the public address system (central amplifier input, Amplified
Addressable Speaker input, etc.).

Table 2. System Assignment

Termination PCBA

Label

Internal Terminal

Pin-Out

Function or ACT Description

EXT DATA GND

TB4-1

No connection

EXT DATA − TB4-2

No connection

EXT DATA +

TB4-3

FLT TB4-4

No

connection

REBOOT TB4-5 No

connection

GND TB4-6

No

connection

AUD ACT 1

TB4-7

Isolated solid state relay, closed during AMI broadcast
On resistance = 30 ohms

AUD ACT 2

TB4-8

The following connections are not used by the Model 10959-906 and 10959-908 Audio Messenger
Interfaces:

Digital outputs (TB1)

Digital inputs (TB2)

Auxiliary Audio (TB5)