Page Line Audio Monitoring Output

The Model LE300-IP Line Extender provides a balanced 600-ohm audio output for monitoring audio on
both the local and remote page lines. The LE300-IP mixes the local and remote page line audio and routes
it to the 600-ohm audio output terminals. This audio can be sent to any external audio device (recorder,
radio transmitter, amplifier, etc.) with an input impedance equal to or greater than 600 ohms. The audio
output gain is adjustable using DIP switch SW3 positions 5–8 on the Main PCBA. Refer to Figure 6 for
the location of Switch SW3 on the Main PCBA and the tables below for setting options.

Table 3. Page Line Monitor Output Gain Setting on Main PCBA

SW3-5

SW3-6

SW3-7

SW3-8

Monitor Output

Gain

Open* Open* Open* Open*

0

dB

Closed Open Open Open

−30 dB

Open Closed Open Open

−27 dB

Closed Closed Open Open

−24 dB

Open Open Closed Open

−21 dB

Closed Open Closed Open

−18 dB

Open Closed Closed Open

−15 dB

Closed Closed Closed Open

−12 dB

Open Open Open Closed

−9 dB

Closed Open Open Closed

−6 dB

Open Closed Open Closed

−3 dB

Closed Closed Open Closed

0

dB

Open Open Closed Closed

+3

dB

Closed Open Closed Closed

+6

dB

Open Closed Closed Closed

+9

dB

Closed Closed Closed Closed

+12

dB

N

OTES

: 1. Changes to this parameter take effect without cycling power.

2.

*Indicates

default

position.