Contact Closure Input Connections

Contact inputs are typically connected to switches or mechanical relay contacts. Five inputs are available
with each input requiring two conductors. Connect the normally open contact across the top and bottom.
If using a solid state switch as the input device, observe polarity of the connection: (−) on bottom, and (+)
on top. Each input cable connection point is labeled next to the terminal block TB8 and TB9 as shown
below.

Figure 14. Input Contact Terminals

Table 28. TB8 and TB9

Terminal Designator Description

TB8

Input 1 (+)

Input contact 1

TB8

Input 1 (−)

TB8

Input 2 (+)

Input contact 2

TB8

Input 2 (−)

TB8

Input 3 (+)

Input contact 3

TB8

Input 3 (−)

TB9

Input 4 (+)

Input contact 4

TB9

Input 4 (−)

TB9

Input 5 (+)

Input contact 5

TB9

Input 5 (−)

Advertising