Applications, Connections – GAI-Tronics 113118-116 Modular TVP Barrier Assembly User Manual

Page 2

Advertising
background image

Pub. 42004-740L2A

Model 13118-016 Modular TVP Barrier Assembly

Page 2 of 3

f:\standard ioms - current release\42004 instr. manuals\42004-740l2a.doc
04/13

Applications

The Model 13118-016 Transient Voltage Protection (TVP) Barrier Assembly is designed to prevent
energy induced on the Page/Party

®

system cable from damaging the Page/Party

®

Interface (PPI) printed

circuit board assembly (PCBA). This assembly also allows party lines 3, 4 and 5 of the local zone to
connect with stations in other zones on the selected party line.

Connections

Table 1. Modular Terminal Blocks (TB1 & TB2) Field Wiring

Pin No.

Function Remarks

1

Page Line – L1

The red/blue wire of the page pair contained within the Page/Party

®

cable is attached to this position of the terminal block.

2

Page Line – L2

The blue/red wire of the page pair contained within the Page/Party

®

cable is attached to this position of the terminal block.

3

Party Line 1 – L1

The red wire of the party line #1 pair contained within the Page/Party

®

cable is attached to this position of the terminal block.

4

Party Line 1 – L2

The tan/red wire of the party line #1 pair contained within the
Page/Party

®

cable is attached to this position of the terminal block.

5

Party Line 2 – L1

The purple wire of the party line #2 pair contained within the
Page/Party

®

cable is attached to this position of the terminal block.

6

Party Line 2 – L2

The tan/purple wire of the party line #2 pair contained within the
Page/Party

®

cable is attached to this position of the terminal block.

7

Party Line 3 – L1

The blue wire of the party line #3 pair contained within the Page/Party

®

cable is attached to this position of the terminal block.

8

Party Line 3 – L2

The tan/blue wire of the party line #3 pair contained within the
Page/Party

®

cable is attached to this position of the terminal block.

9

Party Line 4 – L1

The brown wire of the party line #4 pair contained within the
Page/Party

®

cable is attached to this position of the terminal block.

10

Party Line 4 – L2

The tan/brown wire of the party line #4 pair contained within the
Page/Party

®

cable is attached to this position of the terminal block.

11

Party Line 5 – L1

The yellow wire of the party line #5 pair contained within the
Page/Party

®

cable is attached to this position of the terminal block.

12

Party Line 5 – L2

The tan/yellow wire of the party line #5 pair contained within the
Page/Party

®

cable is attached to this position of the terminal block.

13

Page Line – L1

No field connection (for internal use only)

14

Page Line – L2

No field connection (for internal use only)

15 CLS+

The spare orange wire contained within the Page/Party

®

cable is

attached to this position of the terminal block when All-Call control is
referenced to ground at field stations.

16 CLS−

This terminal is used with CLS+ when dry contact All-Call control is
employed at field stations via a separate pair of wires.

17 EGND

Earth

ground

18 EGND

Earth

ground

Advertising