Installation, Specifications, Reference to assembly/model drawings – GAI-Tronics 113118-116 Modular TVP Barrier Assembly User Manual
Page 3
Pub. 42004-740L2A
Model 13118-016 Modular TVP Barrier Assembly
Page 3 of 3
f:\standard ioms - current release\42004 instr. manuals\42004-740l2a.doc
04/13
Installation
CAUTION
Safety Note: If GAI-Tronics Page/Party
®
cable is used, ensure the ac power conductors are disconnected
from any power source during the installation.
1. Snap the Modular TVP Barrier assembly onto one of the DIN mounting rails located in the cabinet.
2. Connect the appropriate Page/Party
®
cable to modular terminal block TB1 per Table 1 using the
mating plug provided. If the Page/Party
®
cable is looped, connect the "return" side of the cable to
TB2 per Table 1 using the mating plug provided.
3. Attach the appropriate Cat5E cable to the middle RJ45 jack (J2).
4. Attach a ground wire to TB1-17 or TB1-18.
5. If this module is replacing a damaged module, re-connect (plug-in) any cables to/from other modules
at J1 and/or J3.
6. Check and/or set positioning of the party line jumper clips P1 through P3 per the following table:
Table 2.
Jumper Clip Party Line
Installed
Removed
P1 3
Loaded
(33-ohm)
Un-loaded
P2 4
Loaded
(33-ohm)
Un-loaded
P3 5
Loaded
(33-ohm)
Un-loaded
*N
OTE
: Factory default = All jumper clips installed.
Specifications
Mechanical
Dimensions ............................................................................................................. 4.00 H
4.00 W inches
Environmental
Temperature range ............................................................................................................ −30º C to +70º C
Humidity ........................................................................................ 95% non-condensing relative humidity
Reference to Assembly/Model Drawings
Published by
Title
GAI-Tronics Ref. No.
GAI-Tronics
13118-016 Modular TVP Barrier Assembly Drawing
13118-016