Pb4 – tone level adjust – GAI-Tronics IPE2500A, IPE2500A-MLS Paging Encoder / Desktop Controller User and Installatoin Manual User Manual

Page 59

Advertising
background image

IPE2500A and IPE2500A-MLS Paging Encoder/Desktop Controller

Installation

53

03/12

PB4 – Tone Level Adjust

This function is accessible via Main Diagnostics mode select (

PB4

), and allows adjustment of the levels

of sidetone (

PB1

), the alert tones (

PB2

), and the page tones (

PB3

). The tone level adjust will display,

then select

PB1

,

PB2

, or

PB3

.

 The sidetone level used for speaker tones can be adjusted to suit the user.
 The alert and page tone line levels can be adjusted relative to HLGT.

PB1 – Sidetone Level Adjust Mode

This mode allows the adjustment of the sidetone level to −15 dB in 3-dB steps:

Button(s)

Sidetone Level Adjust Mode Function:

VOLUME

Up or

VOLUME

Down

Increases/decreases the sidetone line level. Each time the

VOLUME

Up or

VOLUME

Down button is pressed, a beep is generated and the LCD display shows

the new setting.

TRANSMIT

Exits the sidetone level adjust mode and returns the unit to the tone level
adjustment screen.

PB2 – Alert Tone Level Adjust Mode

This mode allows the alert tone line level to be adjusted to −15 dB relative to the HLGT in 3-dB steps:

Button(s)

Alert Tone Level Adjust Mode Function:

VOLUME

Up or

VOLUME

Down

Increases/decreases the alert tone line level. Each time the

VOLUME

Up or

VOLUME

Down button is pressed, a beep is generated and the LCD display shows

the new setting.

TRANSMIT

Exits the alert tone level adjust mode and returns the unit to the tone level
adjustment screen.

PB3 – Page Tone Line Level Adjust Mode

This mode allows the page tone line level to be adjusted to −15 dB relative to the HLGT in 3-dB steps:

Button(s)

Page Tone Line Level Adjust Mode Function:

VOLUME

Up or

VOLUME

Down

Increases/decreases the alert tone line level. Each time the

VOLUME

Up or

VOLUME

Down button is pressed, a beep is generated and the LCD display shows

the new setting.

TRANSMIT

Exits the page tone line level adjust mode and returns the unit to the tone level
adjustment screen.