5. Feed external ringer cable through the other 0.875-inch hole. Use a wrench to tighten the locking hub

to seal.

6. At the top of the pole: Feed solar panel cable/integrity loop wire , external ringer cable, and the

antenna RG-58 coax cable down through top of pole. Seat pole cap assembly onto pole top.

7. Orient the pole cap assembly for a southern exposure in the northern hemisphere or a northern

exposure in the southern hemisphere as determined by the compass bearing. Secure the assembly by
using the 3 installed tamper-resistant Allen socket-head screws.

8. Adjust the solar panel elevation. Set the panel in accordance with the following chart using

installation site latitude and corresponding tilt angles:

Latitude of

Installation Site

Tilt Angle

0°to 15°

15°

15°to 25°

Angle is same as latitude

25°to 30°

Latitude plus 5°

30°to 35°

Latitude plus 10°

35°to 40°

Latitude plus 15°

Plus 40°

Latitude plus 20°

9. Secure solar panel at the proper angle using tamper-resistant hardware supplied.