Gas equipment assembly – Dometic RM2612 User Manual

Page 11

Advertising
background image

11

free of soot. Heavy soot formation indicates improper
functioning of the burner. The flue and burner both require
cleaning in the following manner:
1) Unplug the refrigerator power cord from the 120 volt

AC outlet (see FIG. 6).

2) Disconnect or shut off the 12 volt power to the

refrigerator.

3) Turn manual shutoff valve to OFF. (See FIG. 6 & 12).
4) Remove cover from the burner housing. (See FIG . 6).
5) Disconnect the wire from the high voltage electrode.
6) Remove the burner mounting screws and remove the

burner assembly.

7) Remove the flue cap from top of flue tube and lift out

the wire and spiral baffle. Clean the flue from the top
using a flue brush. Blowing compressed air into the
flue will not properly clean soot and scale out of the
flue tube. Replace spiral baffle and flue cap.

8) Clean burner tube with a brush. Blow out burner with

compressed air.

9) Before removing burner jet, clean burner area of soot

and scale that fell out of flue tube. Remove the burner
jet. Soak the jet in wood alcohol and allow it to air dry.
Reinstall and tighten burner jet.

FIG. 12

MANUAL SHUT-OFF VALVE
Shown in open position
Use a quarter dollar or a slotted screwdriver
to change p osition

SOLENOID VALVE

BURNER MOUNTING SCREWS

THERMOCOUPLE

BURNER
TUBE

SPARK
ELECTRODE

BURNER
JET

PRESSURE TEST
PORT

INLET FITTING

FIG. 11

GAS EQUIPMENT ASSEMBLY

DO NOT use a wire or pin when cleaning the burner jet
as damage can occur to the precision opening. This can
cause damage to the refrigerator or create a fire hazard.

10) Reinstall burner, being careful that the end of the

burner fits into the slot on the burner bracket. Check
to make sure slots are centered under the flue tube
and the thermocouple is positioned properly (tip of
thermocouple extends over two slots of burner).

11) Be sure to reconnect the wire to high voltage elec-

trode. Check the electrode for proper location and
gap. (See FIG. 11).

ELECTRODE

BURNER T UBE

1/8" T O 3/16"
(3-5 mm)

12) Turn on manual gas shutoff valve and check all

fittings for leaks.

13) Connect 120 volt power cord to the outlet and

reconnect or turn on the 12 volt DC power.

14) Check LP gas safety shutoff. See

Section A. Instal-

lation, Item 9. Testing LP Gas Safety Shutoff.