5. VENTILATION HEIGHTS

Refer to FIG 1., Page 2

Installation with roof

Minimum Ventilation

vent and lower side vent

heights in:

REFRIGERATOR

INCHES

MM

RM2612

54

1372

RM2812

60

1524

LOWER VENT CUTOUT

UPPER VENT CUTOUT

5-1/2"

21-9/16"

13-3/4"

23-3/4"

NOTE: All cutout dimensions are +/– 1/8".

6. CLEARANCES

Minimum clearances in inches to combustible materials are:

G:

Top

0"

K:

Side

0"

L:

Bottom

0"

M:

Rear

0"

N:

See NOTE

NOTE: Clearance "M" is between the rearmost part of the
refrigerator and the wall behind the refrigerator.

NOTE: Clearance "N" is the distance between the bottom
of the lower vent to the roof material. For ventilation
height, refer to

Section A. Installation, Item 5. Ventilation

Heights. See FIG. 2.

FIG. 2

FIG. 3

Refrigerator

Overall

Installation

Recess

Model

Dimensions

Dimensions

Dimensions

Height

Width

Depth

Height

Width

Depth

Height

Width

Depth

A

B

C

h

w

d

H

W

D

RM2612 (Inches)

51

22-23/32

24-9/16

49-7/32

21-17/32

23-19/32

49-17/32

21-13/16

24-3/32

(mm)

1295

577

624

1250

547

599

1258

544

612

RM2812 (Inches) 56-13/16

24-39/64

24-9/16

55-1/8

23-7/16

23-19/32

55-7/16

23-11/16

24-3/32

(mm)

1443

625

624

1400

595

599

1408

601

612