Limited warranty, Specifications, Troubleshooting – Infloor Thermostat 29053 V1 User Manual

Page 2: Operation

Advertising
background image

Limited Warranty

This limited warranty does not cover shipping costs. Nor does it cover a

product subjected to misuse or accidental damage. This warranty does not

cover the cost of installation, diagnosis, removal or reinstallation, or any

material costs or loss of use.

This limited warranty is in lieu of all other warranties, obligations, or liabilities

expressed or implied by the company. In no event shall Infloor Sales & Service

SW be liable for consequential or incidental damages resulting from installa-

tion of this product. Some states or provinces do not allow limitations on how

long an implied warranty lasts, or the exclusion or limitation of incidental or

consequential damages, so the above exclusions or limitations may not apply

to you. This warranty gives you specific legal rights and you may also have

other rights that vary from state to state.

Mount the Relay

1. Carefully fold and press the wires

back into the electrical box. Do not

use the control to push them in, as this

may cause connections to loosen and

possible failure.

2. Secure the Power Module into the box

with the mounting screws provided.

3. Carefully snap the Front Module onto

the Power Module.

4. Tighten the screw.

5. Switch on the power at the main

circuit panel.

NOTE to contractors: After installing

the thermostat, be sure to:

a. Switch on the relay(s)

b. Do a Quick Setup of the master thermostat (see instructions for your

Infloor

thermostat)

c. Temporarily override the thermostat setpoint temperature, making

sure it signals this Relay to begin heating for a few minutes

d. Test the GFCI

(section 3)

5. Specifications

Power Supply

120/240 VAC, 50/60 Hz

Maximum Load

15 amps, resistive

Maximum Power

1800 watts at 120 VAC

3600 watts at 240 VAC

GFCI

Class A (5 milliamp trip)

Storage Temp

0 °F to 120 °F (0 °C to 49 °C)

ETL Listing

Control No. 3037530

4. Troubleshooting

Problem

Solution

Relay works (has green

light) but no heat from

the system.

1. Check signal wire connections at Relay and master

thermostat.

2. Check power wiring connections.

3. If GFCI is tripped, reset Relay.

4. Check resistances on floor warming system. See

manual for system.

No lights showing.

1. Check power wiring connections.

2. Check circuit breaker or other protection “upstream” of

thermostat.

GFCI is tripped.

1. Check wiring connections.

2. Reset Relay by switching off/on.

3. Check resistances on floor warming system. See

manual for system.

3. Operation

On/Off Switch

Your Infloor

Relay should be turned off when

it is first installed.

1. Slide the on/off switch to the upper position,

turning the control on. A green light will show

on the front if power is applied. If the light is

amber, it indicates power is applied to the floor

warming system.

2. To turn the control off anytime, slide the

on/off switch to the lower position. No heating

will occur.

Test the GFCI

There is a GFCI (Ground Fault Circuit Interrupter) inside the Infloor

Relay. It

is designed to help protect people from possible electrical shock if the floor

warming system has been damaged.

To make sure the GFCI is operating, test it after it is installed and once each

month:

1. Make sure the Relay is heating, showing the amber light on the front. You

may need to increase the setpoint temporarily on the master thermostat.

2. Press the GFCI Test button on the side of the control. A red light should

show next to the GFCI Test button. You should also hear a click, indicating

power has been removed from the floor warming system. If any of these indi-

cators fail, turn off the Relay and replace it. Do not continue to use.

3. To reset the GFCI, slide the On/Off switch off and back on. If the GFCI does

not reset, turn the control off and go to section “4 Troubleshooting” for help.

on/off

Infloor Sales & Service SW warrents this control (the product) to be free from

defects in material and workmanship for a period of (2) years from the date of

original purchase from authorized dealers. During this period, Infloor Sales &

Service SW will replace the product or refund the original cost of the

procduct or refund the original cost of the product at Infloor Sales & Service

option, without charge, if the product is proven defective in normal use.

Please return the control to your distributor to begin the warranty process.

Advertising