PART 2 INSTALLATION INSTRUCTIONS

Chemicals
Upon the completed installation of the dishwasher,
contact a local detergent/chemical supplier for
the correct chemicals for your soil load and
geographical area.

Electrical connection points for the detergent
dispenser and rinse injector are located inside the
control panel. Refer to the wiring diagram for this
machine for the proper connection points.

Dispensers may be connected on either the
primary voltage side of the machine or the 24VAC
control voltage side.

CAUTION:

As with any 3 phase system, an electrician must check

all motors for proper phasing, i.e., Pump motors must be

running in direction indicated by arrow on housing.

Mechanical Connections
Connect 140º water lines for tank fill/booster as
tagged and noted on the installation drawings. If
machine is provided with steam heat connect the
steam lines and steam condensate lines as tagged
and noted on installation drawings. Connect the
drain line.

CAUTION:

Drain lines must be as specified on installation

drawings.

Drain line should be properly vented and should have

fall of not less than 1/4” to the foot of proper flow.

Some area plumbing codes require drains

to flow into an open gap with an opening twice

the diameter of the pipe.

Check with your local plumbing codes for the type of

drain connection required.

CAUTION:

All lines must be flushed prior to use to remove debris.

CAUTION:

Do not reduce the size of lines as specified in installation

drawings. All Lines are sized to facilitate necessary

flows, pressures, etc.

HVAC
Ventilation system must be sized to provide ade-
quate ventilation per machine specs. Refer to spec
sheet.

Tabling
Load and unload tables should be pitched towards
the machine to return excess water into the
machine.

Insinger dishmachines are user-friendly, making
them easy to operate and maintain. By following
the operation procedure and general cleaning pro-
cedures your Insinger dishwasher will give you
years of trouble free service.

CAUTION:

When connecting on the 24VAC control voltage side of

the transformer, total VA must not exceed 50VA.

The detergent density probe should be installed in
the hole provided & labeled in the wash tank.
A switch on the control panel labeled “Wash Cycle”
is provided for de-liming the machine. When
activated, this switch will keep the machine in an
indefinite wash cycle. This feature can also be used
to wash heavily soiled ware on an extended wash
cycle.

10