Insinger Commander 18-5 User Manual

Page 21

Advertising
background image

Door Type Series DOC COM 1.0 06

www.insingermachine.com 800-344-4802

Motor Overloads
All motors used on Insinger Machines are provided
with motor overloads. Motor overloads are adjusted
when the machines are factory tested. Should it be
necessary to adjust the motor overloads in the field
first verify the motor current draw for the voltage
the machine is using.

Using the Control Panel Component Layout Dwg.
located in Section 3 to identify the overload adjust
by turning the dial to the appropriate AMP draw.

þ

NOTE:

The overfill timer MUST be adjusted during
initial start-up. Adjustment depends on wa-
ter fill pressure. The water level MUST be
1/4” below the lip of the overflow tube. Ad-
just by increasing or decreasing the potenti-
ometer on the level timer.

þ

NOTE:

Dirty level floats will cause the tank heat to
energize with no water in the tanks.
LEVEL FLOATS MUST BE CLEANED
DAILY.

PART 3 MAINTENANCE & REPAIR PROCEDURES

Level System
The level control system consists of one overfill
timer (P/N DE7-35) and one level float (P/N DEF-
60) per tank.

When the system is powered-up, the tank(s) will
begin to fill (assuming no water is in the tanks).

When the level float is actuated, the overfill timer
begins to time-out and continues the filling process
until the tank(s) is full.

Liquid Level Timer DE7-35

Sk-4698

19