Divesting – Ivoclar Vivadent IPS InLine System User Manual

Page 65

Advertising
background image

65

divesting

Once the investment ring has cooled to room temperature (approx. 60 min), divest as fol-
lows:
– Mark the length of the Alox plunger on the cooled investment ring.
– Separate the investment ring using a separating disk. This predetermined breaking

point enables reliable separation of the investment material and the ceramic material.

– Always use polishing beads to divest the pressed objects (rough and fine divestment).

Do not use Al

2

O

3

.

– Rough divestment is carried out with polishing beads at 4 bar (60 psi) pressure.
– Fine divestment is carried out with polishing beads at 1–1.5 bar (15–22 psi) pressure.
– Observe the blasting direction and distance to prevent damage to the object margins

during divestment. Cover the marginal areas thoroughly with the glove.

Separate the investment ring using a separating disk.

The Alox plunger is already very clean if it is removed with tongs from the investment material. Check the cleanness and blast with Al

2

O

3,

if required.

Sandblasting the objects

Mark the length of the Alox plunger.

IPS
InLine

PoM

– Accurate Press-On Technique