7

Warning

– Hexane is highly flammable and detrimental to health. Avoid contact of the material with skin and eyes. Do not inhale vapours. Keep

away from sources of ignition.

– Avoid inhaling grinding dust when working on ceramic restorations. Use suction equipment or protective masks.

Composition

IPS InLine One

IPS InLine

IPS InLine PoM

– IPS InLine ceramic Materials
Leucite ceramic based on alcalialumo

silicate glasses and feldspar

– IPS InLine Margin Build-Up Liquid
Water and cellulose derivative

– IPS InLine One ceramic Materials
Leucite ceramic based on alcalialumo

silicate glasses and feldspar

– IPS InLine PoM Ingots
Leucite ceramic based on alcalialumo

silicate glasses

– IPS InLine PoM touch-Up Materials
Leucite ceramic based on alcalialumo

silicate glasses

– IPS e.max AlOx Plungers
Al

2

O

3

IPS e.max AlOx Plunger Separator
Boron nitride

– IPS PressveSt Powder
SiO

2

(quartz powder), MgO and NH

4

H

2

PO

4

– IPS PressveSt Liquid
Colloidal silicic acid in water

– IPS PressveSt Speed Powder
SiO

2

(quartz powder), MgO and NH

4

H

2

PO

4

– IPS PressveSt Speed Liquid
Colloidal silicic acid in water

– IPS InLine System Shade / Stains / Glaze
Ceramic materials and glycols

– IPS InLine System Build-Up Liquids L and P

Water, glycols and additives

– IPS InLine System Powder Opaquer Liquid
Water, glycols, acetic acid, additives

– IPS InLine System Opaquer Liquid
Butylene glycol, glycerine, thickening agent

– IPS InLine System Glaze and Stains Liquid
Butandiol

– IPS Model Sealer
Ethyl acetate, nitro-cellulose, softener

– IPS ceramic Separating Liquid
Paraffin oil

– IPS Margin Sealer
Wax dissolved in hexane