Operation and configuration – Ivoclar Vivadent EP 5010 User Manual

Page 24

Advertising
background image

24

STOP key
A program in progress can be paused by pressing the STOP key and stopped by pressing
STOP twice. Movement of the furnace head can be stopped at any time by pressing
STOP. Acoustic signals can be confirmed by pressing the STOP key.

START key (Start LED)
Starts the selected program. The green LED indicates that a program is active. If the
program is paused (1x STOP), the Start LED flashes until renewed pressing of START
results in the program being resumed.

5.1.3 Explanation of the most important touch buttons

Button

Function

Scroll left / Scroll right
With these buttons, you can e.g. scroll to page 2 of the home screen.

Back with note
With this button, you can change to the "next higher" menu level. The button indicates
to which screen you change, e.g. to the home screen.

Close
With this button, you can leave sub-menus.

Confirm entry
This button is used to confirm an entry. If the button appears pale green, no entry has
been made yet or the value entered is not in the acceptable range.

Cancel entry
This button is used to cancel an entry. Changed values are not saved.

Program parameters
Pressing these buttons allows you to change program parameters. A selection list or
numeric pad for entering the values appears.
The upper half of the button itself shows the parameter in question (e.g. closing time),
while the lower half shows the entered value (e.g. 00:18).

On / Off button
This button is used to switch functions on or off.

Parameters
By pressing these buttons, a selection list or numeric pad for entering the values
appears.

5.1.4 Explanation of the numeric pad and selection list
– Numeric pad
The numeric pad enables the entering and changing of parameters, e.g. in firing

programs or setting menus. Additionally, the currently set value as well as the
minimum and maximum values are indicated.

An entry must be confirmed with the green button. As soon as the entry has

been confirmed, the numeric pad is closed. If the button appears pale green, the
value is not in the acceptable range.

The numeric pad can be closed with the red button, without any parameters

being changed.

5. Operation and Configuration

Advertising